mgo mineral insulated thermocouple cable
"
Solid Copper Conductor Single Core Mineral Insulated Metal Sheathed Cable with 0.5-12.7mm Outside Dia for High Temperature Applications
Mineral Insulated Metal Sheathed Cable with Solid Copper Conductor Single core design engineered for high temperature environments with superior performance and reliability. Product Specifications Type: K/N/E/J/T/S/R/B Place of Origin: Zhejiang, China Accuracy: I-0.4%t, II-0.75%t, III-1.5%t Core number: 2, 3, 4, 6 Inorganic mineral insulating lead material: Ni, Cu Insulator: 99.6% high purity MgO Certificate: ISO9001, IATF16949, CE Application: Connecting with thermocouple
Kabel Berinsulasi Mineral Akurasi Tinggi dengan Selubung Logam dengan Panjang yang Dapat Disesuaikan dan Sertifikasi ISO9001
Mineral Insulated Metal Sheathed Cable for High Temperature Environments Quick Details Type: K/N/E/J/T/S/R/B Place of Origin: Zhejiang, China Accuracy: I-0.4%t, II-0.75%t, III-1.5%t Core number: 2,3,4,6 Inorganic mineral insulating lead material: Ni, Cu Insulator: 99.6% high purity MgO Certificate: ISO9001, IATF16949, CE Application: Connecting with thermocouple and instrument machine Sheath material: 0Cr18Ni10Ti, SS304S, SS316L, SS316, Cu Sheath Dia(mm): φ3.0, φ4.0, φ6.0, φ8
Kabel Berinsulasi Mineral Tipe K/N/E/J/T/S/R/B 1-5m 200℃-1000℃
K/N/E/J/T/S/R/B Types Mineral Insulated Metal Sheathed Cable and Durable for Long-Term Performance Product Specifications Quick Details: Type: K/N/E/J/T/S/R/B Place of Origin: Zhejiang, China (Mainland) Accuracy: I-0.4%t, II-0.75%t, III-1.5%t Core number: 2,3,4,6 Inorganic mineral insulating lead material: Ni, Cu Insulator: 99.6% high purity MgO Certificate: ISO9001, IATF16949, CE Application: connecting with thermocouple and instrument machine Sheath material: 0Cr18Ni10Ti,
Mineral Insulated Metal Sheathed Cable with 2-6 Core Options ISO9001 IATF16949 CE Certified and 0.5-12.7mm Outside Diameter
K/N/E/J/T/S/R/B Types Mineral Insulated Metal Sheathed Cable Durable for long-term performance in industrial applications. Product Specifications Quick Details: Type: K/N/E/J/T/S/R/B Place of Origin: Zhejiang, China (Mainland) Accuracy: I-0.4%t, II-0.75%t, III-1.5%t Core number: 2,3,4,6 Inorganic mineral insulating lead material: Ni, Cu Insulator: 99.6% high purity MgO Certificate: ISO9001, IATF16949, CE Application: Connecting with thermocouple and instrument machine Sheath
Industrial-Grade Mineral Insulated Metal Sheathed Cable with Customizable Length and Multiple Thermocouple Types ISO9001 Certified
Industrial-Grade 2-6 Core Mineral Insulated Metal Sheathed Cable High-performance cable designed for heavy-duty applications with thermocouple and instrument machine connections, featuring a temperature range of 200℃-1000℃ and Class I/II/III accuracy. Quick Specifications Type K/N/E/J/T/S/R/B Place of Origin Zhejiang, China (Mainland) Accuracy I-0.4%t, II-0.75%t, III-1.5%t Core number 2,3,4,6 Insulator 99.6% high purity MgO Certificate ISO9001, IATF16949, CE Sheath material
Kabel Berlapis Logam Berinsulasi Mineral Tugas Berat 2 hingga 6 Inti Tingkat Industri untuk Termokopel dan Instrumen untuk Kinerja
Industrial-Grade 2-6 Core Mineral Insulated Metal Sheathed Cable High-performance cable designed for heavy-duty applications with thermocouple and instrument machine connections, featuring a temperature range of 200℃-1000℃ and Class I/II/III accuracy. Quick Specifications Type K/N/E/J/T/S/R/B Place of Origin Zhejiang, China (Mainland) Accuracy I-0.4%t, II-0.75%t, III-1.5%t Core number 2,3,4,6 Insulator 99.6% high purity MgO Certificate ISO9001, IATF16949, CE Sheath material
Kabel Termokopel Berinsulasi Mineral Keandalan Tinggi dengan Rentang Suhu 200°C-1000°C, Akurasi Kelas I/II/III, dan Selubung SS316
Quick Details: Type: K/N/E/J/T/S/R/B Place of Origin: Zhejiang, China (Mainland) Accuracy: I-0.4%t, II-0.75%t, III-1.5%t Core number: 2,3,4,6 Inorganic mineral insulating lead material: Ni, Cu Insulator: 99.6% high purity MgO Certificate: ISO9001, IATF16949, CE Application: connecting with thermocouple and instrument machine Sheath material: 0Cr18Ni10Ti, SS304S,SS316L,SS316, Cu Sheath Dia(mm): φ3.0, φ4.0, φ6.0, φ8.0 Type for Sheath Wire Type K: Product Name Code Type Shaeth
4 inti kabel termokopel presisi tinggi untuk pengukuran suhu yang tepat
Quick Details: Type: K/N/E/J/T/S/R/B Place of Origin: Zhejiang, China (Mainland) Accuracy: I-0.4%t, II-0.75%t, III-1.5%t Core number: 2,3,4,6 Inorganic mineral insulating lead material: Ni, Cu Insulator: 99.6% high purity MgO Certificate:ISO9001, IATF16949, CE Application: connecting with thermocouple and instrument machine Sheath material: 0Cr18Ni10Ti, SS304S,SS316L,SS316, Cu Sheath Dia(mm): φ3.0, φ4.0, φ6.0, φ8.0 Type for Sheath Wire Type K: Product Name Code Type Shaeth
MIMS Fe-Konstantan / Cu-Konstantan Mineral Insulated Metal Sheathed Cable
Quick Details: Type: K/N/E/J/T/S/R/B Place of Origin: Zhejiang, China (Mainland) Accuracy: I-0.4%t, II-0.75%t, III-1.5%t Core number: Single / Double Insulator: 99.6% high purity MgO Certificate:ISO9001, IATF16949, CE Application: connecting with thermocouple and instrument machine Conductor material: NiCr-NiSi, NiCrSi-NiSi, NiCr-Konstantan, Fe-Konstantan, Cu-Konstantan Sheath material: Inconel600, 0Cr18Ni10Ti, SS304S,SS316L, SS310,SS316,GH3030, GH3039, GH747 Sheath Dia(mm):